Selamat Datang di Indotrade.com
Masuk | Daftar
Anggota Prioritas Prioritas IndotradeTahun ke-15
CV. ANDALAN PRIMA SEJAHTERA ( andalan_ prima@ yahoo.com)
http://indotrade.com/andalanprimasejahter/
`CV. ANDALAN PRIMA SEJAHTERA, Telpon: + 62-21-29253184, 021-29253187, 46560833, 46560834, Fak: 021-29253186 Email : support@andalanprimasejahtera.com
Informasi Kontak
Nama:

Tn. Enangkholis / Heru [Direktur/CEO/Manajer Umum]

E-mail:
Pesan Instan:

ICQ: andalanprimasejahtera
Google Talk:  www.andalaninstrument.com  www.andalaninstrument.com
Y!: edy_girsangta@yahoo.com 
Nomor Telpon:

Nomor telpon Tn. Enangkholis  / Heru di bekasi utara - Indonesia

Nomor Ponsel:

Nomor ponsel Tn. Enangkholis  / Heru di bekasi utara - Indonesia

Nomor Faks:

Nomor faks Tn. Enangkholis  / Heru di bekasi utara - Indonesia

Alamat:

Jl. Muhtar Tabrani Perum Bintang Metropol Blok A-7/16
bekasi utara - Indonesia 17122
Indonesia

Alamat Tervalidasi

http: / / www.andalaninstrument.com
Rata-rata Tinjauan Pemakai

Tidak ada ulasan untuk perusahaan ini

Menulis tinjauan
Bahasa :

Jual

KYORITSU 1061/ 1062[15 Jun. 2011, 12:42:20]
Hargainquiry
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Kemas & Pengirimanoriginil
Negara AsalJepang
High Accuracy, High Performance and Reliable Measurements :

• 0.02% basic DC accuracy
• Large display with 50, 000 counts
• Dual display for double indication for AC and DC, V and Hz, etc.
• True-RMS Measurements AC and AC+ DC
• Wide AC Frequency bandwidth from 10Hz to 100kHz *
• True-RMS or MEAN value detection mode can be selected *
• Fast Peak Hold response time of 250µ s
• Low-pass filter for motor drive measurements *
• Low Power © for resistance measurements on sensible electronic circuits by a low and safe test current *
• User calibration function
* Only for KEW 1062

Safety design for industrial use :

• Complies with IEC 61010-1 CAT.III 1000V, CAT.IV 600V
• Terminal shutter to prevent incorrect test leads' insertion in current terminals
• Very wide operating temperature range from -20 to 55º C

Reliable support for data management :
• Large data internal memory
KEW 1062: 10, 000 data ( logging) , 100 data ( manual)
KEW 1061: 1, 000 data ( logging) , 100 data ( manual)
• Download data and Live Monitoring on a PC via the USB interface
( Option for USB Communication set)

Detection mode : RMS MEAN/ RMS ( switch) ( KEW 1061 KEW 1062 )
DC V 50.000/ 500.00/ 2400.0mV/ 5.0000/ 50.000/ 500.00/ 1000.0V
( Input impedance: Approx. 100M© [ 50/ 500/ 2400mV] , 10M© [ 5/ 50/ 500/ 1000V]
| ± 0.02% rdg± 2dgt ( Basic accuracy) ( KEW 1061 KEW 1062 )
AC V
[ RMS] 50.000/ 500.00mV/ 5.0000/ 50.000/ 500.00/ 1000.0V
( Input impedance: 11M©